ENV-THUMTemperature & Humidity Sensor for mission critical facilities
Measures relative humidity between 10% and 90% at ±2% accuracy.
Resolution of 0.1% rH.
Humidity probe made in Switzerland, tested against national standards.
Calibratable — unlike most digital rH sensors.
Optional humidity & ISO 17025 temperature calibration certificates.
Optional UL Recognized version (ENV-THUM-L).
Plug & play — SNMP, Modbus TCP, BACnet IP & MQTT ready.
Resolution of 0.1% rH.
Humidity probe made in Switzerland, tested against national standards.
Calibratable — unlike most digital rH sensors.
Optional humidity & ISO 17025 temperature calibration certificates.
Optional UL Recognized version (ENV-THUM-L).
Plug & play — SNMP, Modbus TCP, BACnet IP & MQTT ready.
Swiss Made Humidity Probe
Humidity is the underestimated threat. The sensing component is made in Switzerland and tested against several national standards.
Calibratable, Not Disposable
Most digital rH sensors cannot be recalibrated — when they lose accuracy you buy another. This one goes back to the lab instead.
Sensor Drifting
Every rH sensor drifts, because it breathes the air it measures. Indoor sensors should be calibrated at least once a year.
Selecting a Humidity Sensor
Precision, accuracy, resolution, calibratability and dew point — five criteria, and why most vendors only publish one of them.
ASHRAE Humidity Tips
Condensing humidity shorts equipment; low humidity builds static. The recommended envelope, ESD mitigation and why dew point matters.
Daisy Chain Option
A base unit takes 8 sensors with the Sensor Hub. Beyond that, the daisy chained version connects many more on a single port.
Humidity & Infectivity
Relative humidity below 40% or above 60% increases the infectivity rate of airborne viruses — relevant wherever people share the space.
Where to Deploy
Rack level versus ambient, and the application guide for setting up a rack level temperature & humidity measurement.
UL Recognized Option
The ENV-THUM-L is the UR 61010 (UL Recognized) version, for installations where that is a condition of acceptance.
How It Works
Connects to the base unit over standard network cable. The base unit is standalone, with no PC or software required.
Flexible Integration
Readings and alerts over SNMP GET & TRAPS, Modbus TCP, BACnet IP, MQTT and JSON.
Technical Specifications
View measurement ranges, accuracy, resolution, calibration options and connectivity for the ENV-THUM.
Humidity is underestimated as a threat to infrastructure. Everyone knows about temperature and its risks, but many are unaware that humidity is an equally significant one.
The humidity component inside the sensor is made in Switzerland and is tested against several national standards.
Most digital relative humidity sensors on the market are not calibratable. When they lose accuracy you are forced to buy a replacement — without knowing whether the replacement is accurate either.
The effect of humidity on equipment is well known. Its effect on the transmission of viruses is less so.